Cold-sprayed graphene sensor sticks to skin, tested on one person

Languages for this article
Original · ENDEESFRITPT

Originally written in English. 6 languages available; yours is one click away.

Illustrative photo: US Troops test experimental ‘Wearables Pilot Program’ technology at Exercise Talisman Sabre 2023 (7925665)
Illustrative photo: U.S. Army video by Sgt. 1st Class Timothy Hughes · Public domain · Wikimedia Commons

A wearable sensor has usually meant a device glued onto the body, built in several costly steps. A team from two American universities has tried another route: spraying the sensing material straight onto the flexible surface that touches the skin.

The device is a pressure sensor made of PDMS, the polydimethylsiloxane polymer, a soft, stretchy rubber that molds to wherever it is applied. The researchers use a cold-spray technique to deposit graphene nanoplatelets onto that rubber, which Arvind Agarwal, chair of the mechanical and nuclear engineering department at Virginia Commonwealth University, says can be done "without glue or several complicated steps". Traditional adhesion methods require heating or adding chemicals and binders; the cold spray works dry, at room temperature, and does not alter the other materials in the sensor. The work was carried out with materials scientists at Florida International University, co-authors Azmal Huda Chowdhury, Denny John, Anil Lama and Rony Thomas Murickan, and was published in ACS Applied Electronic Materials.

In the experiments, the sensor responded in 29 milliseconds to a press-and-release, kept working after more than 5,000 presses, and was able to pick up a person's wrist pulse. These are laboratory tests run on a single human subject. The results come from the team's own experiments.

What changes, for whom? Device makers who need low-cost, expandable sensors are the first audience, because the authors present the method as a way to reduce the number of fabrication steps and to make manufacturing scalable. Patients who rely on continuous monitoring would benefit only if that scalability is demonstrated and the sensor is tested on more people. The team does not announce any commercial partner, price or calendar, and the study leaves open how soon such devices could reach a clinic or a consumer.

29 millisecondsReaction time of the graphene pressure sensor to a press-and-release, measured in lab tests