Aube.Tuesday, 24 November 2026Support us

Aube.

News of progress
PrototypeSingle source

Dry putty electrode matches clinical electrode, in proof of concept

Languages for this article
Original · ENDEESFRITPT

Originally written in English. 6 languages available; yours is one click away.

Illustrative photo: McGill University downtown campus August 2017 01
Illustrative photo: Arild Vågen · CC BY-SA 4.0 · Wikimedia Commons

Speech pathologist Nicole Li-Jessen knows the problem well. She can prescribe muscle-strengthening exercises to her patients, but she sees them 30 minutes a week, or even monthly. Between visits, nobody can check whether the exercises are done correctly. A team of McGill University researchers has now built an electrode that could close that gap: a dry, putty-like sensor that molds to the neck and records small muscles as well as a standard clinical electrode.

Electromyography (EMG) sensors read the electrical activity of muscles through electrodes placed on the skin. They work well on large areas such as the legs and arms. The neck is harder, because its muscles are small and the surface is strongly curved, and most commercial sensors need a gel to stick to the skin and carry the signal. The gel eventually dries out and adds noise. The new sensor is made of a soft, silicone-based putty that conducts electricity through tiny silver wires. Because it needs no gel, it lies closely against the skin, with little air between the two to disturb the signal.

The most surprising property came from the material itself. "Its surprising feature is that stretching it makes it conduct electricity even better," said senior author Jianyu Li, associate professor of mechanical engineering. "As the putty stretches, the wires rearrange, helping the electricity keep flowing." To test the device, the researchers shaped the putty into neck electrodes and recorded three volunteers completing vocal tasks designed to induce fatigue, which also checked how the sensor behaved at low muscle signal levels. Its noise and stability matched a standard clinical electrode. Li-Jessen stressed that the study is a proof of concept, not a clinical trial, and that it shows the electrode records clean signals from small neck muscles where standard electrodes struggle.

The practical gain is at home. A sensor that gives feedback during exercises would let a patient see whether the right muscle is working, and the team says it could help track breathing, swallowing and speaking during rehabilitation after a stroke or in neurodegenerative diseases such as Parkinson's. Clinicians would then see what happens between appointments instead of guessing. Before that, the team says larger studies and regulatory approval are needed, and no clinical date has been announced. The next step is therefore a bigger group of patients, which will show whether a result obtained with three volunteers holds across a population.

Sources — read the originals(Paris time)

Medical XpressEN
0000

Read next

Comments

Loading the thread…