Cameras expose a hidden misalignment in a four-meter-class mirror

Languages for this article
Original · ENDEESFRITPT

Originally written in English. 6 languages available; yours is one click away.

Illustrative photo: Primary mirror and telescope structure (noirlab- u3s0018)
Illustrative photo: International Gemini Observatory/NOIRLab/ NSF /AURA/M. Paredes · CC BY 4.0 · Wikimedia Commons

Polishing a mirror in the four-meter class means chasing errors measured in micrometers. Researchers at the Changchun Institute of Optics, Fine Mechanics and Physics, part of the Chinese Academy of Sciences, have found a way to catch one of them while the work is still underway: a fixed offset between two surfaces built into the same piece. Their method, described in the journal Measurement in 2026, combines machine vision with interferometry and reaches a combined standard uncertainty of 31 micrometers on a four-meter-class monolithic mirror.

Large optical systems increasingly use monolithic mirrors, single components that carry several reflecting surfaces. When the primary and tertiary surfaces are made on the same blank, their relative position is set during fabrication. A lateral displacement between their optical axes cannot be corrected afterwards by adjusting separate mounts, and it degrades imaging. The offset therefore has to be measured during polishing and final inspection, while the results can still guide the work.

The difficulty is that an interferometer, which reads the shape of light waves reflected from the mirror, responds to two different errors. One is the intrinsic offset between the surfaces. The other is a temporary sideways shift of the test beam when the instrument is aligned with the mirror. Both produce a similar aberration called coma, so optical data alone cannot separate them reliably. Conventional setups also pass references through several mechanical stages, letting small alignment errors accumulate, and repeated realignment makes it harder to compare results from different manufacturing stages.

The team's answer is a second, independent ruler. Four industrial cameras were arranged around the mirror along two perpendicular directions, observing the crosshair projected by the interferometer against the mirror's reference features. Synchronized images were combined in a rigid-body model that separates sideways movement from rotation, and calibration corrected for the reference plate and camera mounting. With the beam's lateral movement known directly from the cameras, its contribution to the coma can be computed and removed from the wavefront data, leaving the mirror's own offset. Tests at different alignment states checked the separation, and the method was run during a polishing cycle, giving feedback while the mirror was still being manufactured.

For makers of large optical systems, the gain is that a misalignment can be found and corrected before the mirror is finished, rather than after assembly, when a mount can no longer compensate for it. The current version measures sideways offset in a single plane, not every component of the mirror's relative pose. The researchers say future work could extend the method through three-dimensional vision measurement, which is the next step they name. The study gives no timetable for industrial use.