Aube.Tuesday, 24 November 2026Support us

Aube.

News of progress
LabSingle source

Lab test: one X-ray optic images 27 times faster and reads chemistry

Languages for this article
Original · ENDEESFRITPT

Originally written in English. 6 languages available; yours is one click away.

Generated illustration for “Lab test: one X-ray optic images 27 times faster and reads chemistry”
AI-generated illustration — artist’s view, not documentary

For decades, mapping the inside of a material with X-rays has meant a trade-off. Imaging shows where things are; spectroscopy shows what they are made of. Each usually needs its own stack of optics, carefully aligned. At the P04 beamline of PETRA III, the synchrotron radiation source at DESY in Hamburg, a team from Germany, Switzerland and Japan tested a different route with one component. Their reflection zone plate (RZP), a nanostructured reflective optic, reflects, focuses and separates soft X-rays at the same time.

Instead of scanning one tiny point at a time, the researchers lit the sample with a narrow X-ray line and moved it in small steps across the beam, like a document passing through a scanner. A computer stitched the strips into a two-dimensional image. The system resolved features of 14 to 24 micrometers, several times smaller than a human hair. Because it scanned a whole line at once, it imaged circular objects about 27 times faster than the conventional method, while keeping comparable image quality.

The obstacle was optical. The Abbe sine condition, a classic principle, predicts image distortions under certain conditions, and the researchers said such imaging was previously thought to be unworkable because of it. They got around the problem by operating the RZP in the paraxial regime, so that it collects only X-rays travelling within a narrow angular range. That lowered the distortions and made sharp images of larger objects possible.

For the chemistry test, the sample became a thin jet of acetonitrile dissolved in ethanol, lit by a beam carrying many energies at once, what the researchers call an X-ray “rainbow”. The RZP measured the energies of incoming and outgoing X-rays simultaneously, which produced a full two-dimensional resonant inelastic X-ray scattering (RIXS) map between 388.6 and 401.8 electron volts (eV), around the nitrogen K-edge. The entire dataset took about 220 seconds. Dr Christoph Braig noted that the elastic and inelastic signals are recorded in the same optical configuration.

For laboratories that run soft X-ray measurements, the change is a more compact setup. Jens Rehanek said the arrangement “could make advanced soft X-ray measurements more efficient and easier to implement.” Zhong Yin, at the Synchrotron Radiation Instrumentation Science Laboratory of Tohoku University, sees in the combination of reflection, focusing, imaging and spectral dispersion “a compact and efficient route to soft X-ray spectromicroscopy”, which could open studies of materials at the atomic scale. That last step is an outlook: the reported resolution is in micrometers, and the study sets no timeline for use beyond these synchrotron experiments.

27 times fasterto image circular samples than point-by-point scanning, with comparable quality (lab test)

Sources — read the originals(Paris time)

Interesting EngineeringEN
0000

Read next

Comments

Loading the thread…

Sign in to leave a comment. Sign in