In beamline tests, AI rebuilds 3D chip X-ray images in real time

On a chip made with 22-nanometer technology, a segment about 20 micrometers wide was imaged and rebuilt in 3D at the Hard X-ray Nanoprobe, the X-ray microscope at Brookhaven National Laboratory’s NSLS-II facility. The approach that made it possible combines machine learning with the instrument itself, not just with the data afterward.
Until now, the usual sequence was simple and slow. Researchers collected a complete set of measurements, then reconstructed the image and examined it. Ptychographic tomography, a technique that builds detailed 3D images from many individual measurements, depends on a reconstruction process that is computationally intensive. The SYNAPS-I team, a multilaboratory project under the Department of Energy’s Genesis Mission, set out to let analysis start while the experiment is still running.
In a first demonstration, an automated experiment analyzed images as they were acquired, identified scientifically interesting regions in a complex sample and selected those areas for high-resolution measurement, without human intervention. “This enables an automated experiment to run for hours, surveying a large area, and collect high-fidelity data only from scientifically important locations,” said Daniel Allan, who leads the Data Engineering Group at NSLS-II.
In a second demonstration on microelectronic chips, a foundation model trained at Argonne replaced the iterative reconstruction. Working with NVIDIA, the team integrated the workflow into the NVIDIA Holoscan platform and reached 200 images per second in real-time reconstruction. A model developed at NSLS-II reconstructed a microchip from nearly one-tenth of the data normally required, and the team fine-tuned Meta’s open-weight Segment Anything Model 3 (SAM3) to identify materials, structures and regions of interest in the resulting 3D data.
For beamline users, the gain is practical: scans that need less time and less radiation dose, and 3D data that can be interpreted faster. Hanfei Yan, lead beamline scientist at the Hard X-ray Nanoprobe, said the workflows already help users “make better use of their limited beam time.” The team cites buried structures and defects in microelectronics, degradation in battery electrodes and complex nanomaterials as possible applications. These are demonstrations on a small number of chips, and the team gives no date for wider use.
The next target is real-time tomography. Today, the final 3D image appears only after a full projection data set is collected. In the workflow the team describes, reconstruction would begin during the experiment, with a lower-resolution image improving as measurements accumulate.