Aube.Tuesday, 24 November 2026Support us

Aube.

News of progress
LabSingle source

In lab tests, xenon spots MRI gadolinium at micromolar levels

Languages for this article
Original · ENDEESFRITPT

Originally written in English. 6 languages available; yours is one click away.

Illustrative photo: DKFZ Heidelberg 01
Illustrative photo: Kuebi = Armin Kuebelbeck · CC BY-SA 3.0 · Wikimedia Commons

Just under half of all MRI scans rely on a gadolinium-based contrast agent, and the metal does its work inside the body before leaving it. Gadolinium is held in a so-called chelate, a molecular cage, and it interacts with water in tissue to make some areas look brighter on the scanner. After the scan, the agent is excreted in urine and ends up in wastewater, where the metal stays locked in its cage in the long term. A team at the German Cancer Research Center (DKFZ), led by Leif Schröder, has now found a way to detect that metal in solution down to the micromolar range.

The method combines two effects. The researchers use hyperpolarized xenon, a noble gas magnetized so that it produces a strong MRI signal. Xenon sits in a separate cage molecule, cryptophane-A, and produces two distinct signals: one for xenon bound in the cage, one for xenon floating free in the solution. When gadolinium is added, it displaces the xenon from the cage, so the bound signal shrinks and eventually disappears. “From the reduction in the xenon signal, we were able to determine the concentration of gadolinium outside the cage,” says Hannah Gerbeth, the study's lead author.

The DKFZ team found that concentrations in the micromolar range can be measured under the conditions of the experiment, which makes the cage molecule a highly sensitive sensor. “This discovery shows that the unique properties of the interaction between gadolinium, xenon and the cage enable more sensitive detection than was possible in previous research using MRI,” Schröder says. The method also separates free gadolinium from the chelated form, which matters for both clinical use and monitoring of gadolinium-containing substances in the environment. Schröder stresses the need for such tools, not only for contrast agents but also for industrial processes. The results so far come from laboratory solutions.

For clinicians and environmental monitoring teams, the gain is a more sensitive way to tell free gadolinium from the bound form that is currently excreted. The study does not say when such a tool could reach hospitals or water-treatment sites.

The next steps are already set. The scientists plan to test the sensor across other concentration ranges. They also want to find out whether other ions are bound by the cage, since such ions could interfere with the gadolinium measurement.

Sources — read the originals(Paris time)

Medical XpressEN
0000

Read next

Comments

Loading the thread…

Sign in to leave a comment. Sign in