A patient breathes into a device, and a few drops of liquid are gathered from the air that leaves the lungs. For chronic obstructive pulmonary disease (COPD), a condition that makes breathing harder as it worsens, that simple gesture could replace blood draws or costly CT scans. The method, called exhaled breath condensate (EBC), was first proposed in the 1970s. Its problem has never been the collection itself but the numbers: repeat the same measurement and the results do not agree.

For decades, the prevailing view held that this variation was biological, which left little hope of standardizing the test. Jingcheng Ma's group at the Interfacial Thermofluids Laboratory of the University of Notre Dame took a different path and looked at the collection process itself, in particular the switch between gas and liquid phases. Their paper in Nano Letters drops the assumption that the amount of biomarkers stays constant in a sample. Using a fluorescence platform built in the lab to follow droplets, the team showed that droplets can lose significant biomarker content within a single breath cycle, through evaporation. They then built a mathematical model for one droplet and extended it to the population of droplets that forms on a real condenser surface.

The tests, which mimicked patient collection by controlling breath duration, pauses and collection time, pinned down two concrete factors. Droplet size determines whether significant losses occur at all, and pauses between breaths correspond to greater evaporative losses. The researchers also flagged ambient temperature, humidity and the temperature of the collection plate as variables still to be studied. Amio Ritwik, a doctoral student and the paper's lead author, sees the result as a first step: the errors are measurable, so a standard becomes conceivable. The next task is to separate the parameters that drive the variation.

For patients, the stakes are broad. Ma notes that EBC could change the standard of care for COPD, diabetic patients and preterm infants, and for under-resourced or remote populations that have no easy access to a laboratory. The chain is explicit: once the variability is corrected, new collectors could be designed that can be trusted in the clinic. The team has not announced a timeline, nor a device, and these results come from laboratory experiments, not from patients.

The group now plans to work with researchers from other disciplines, clinicians, and device developers. Ma describes the lab as “a bridge connecting the engineering efforts to the planning efforts,” and the next stage will be to turn that bridge into partnerships.