Breath sensor detects liver-linked gas at 10 ppb

A sensor built in Hefei can pick out a trace gas in human breath at 10 parts per billion (ppb), even when the air is 90% humid and a rival gas is present. The gas is dimethyl sulfide. It is normally found in breath at low concentrations, and levels above 30 ppb have been associated with liver conditions such as cirrhosis and hypermethioninemia.
The difficulty was selectivity. Hydrogen sulfide, another gas commonly found in breath, interferes with the detection of dimethyl sulfide, and humidity adds a second problem. The team, from the Hefei Institutes of Physical Science of the Chinese Academy of Sciences, with the Key Laboratory of Odor Pollution Control of the Ministry of Ecology and Environment and Shenzhen Technology University, added a thin filter of copper oxide and aluminum oxide in front of its palladium–tungsten oxide sensing material. The filter captures hydrogen sulfide before it reaches the sensing material and lets dimethyl sulfide pass. A review of selectivity in gas sensors notes that aluminum oxide is hydrophilic, which is why it can also filter out moisture. With the filter in place, the ratio of response between the two gases rose from 3.3 to 50.4, according to the paper published in ACS Nano.
On breath samples designed to simulate those of liver disease patients, the sensor registered small changes in dimethyl sulfide concentrations. Simulated samples are not patient samples, and the team's results have not yet been tested in a clinic. Other work points in the same direction without settling the question. A pilot study reported on nature.com shows dimethyl sulfide in breath higher in liver patients than in healthy people. A review of breath and blood ammonia in liver cirrhosis cites a rise from 10 to 60 ppb in liver disease, a wider band than the 30 ppb threshold the team works from. A study of breathprints in patients with alcoholic hepatitis, meanwhile, found no differences in breath levels of dimethyl sulfide.
For clinicians, the appeal is a screening route that works from a breath sample, which is the aim the researchers give: noninvasive liver disease screening. Who would gain, and when, is not yet set. The team has announced no timetable and no clinical study. Related work is moving on the same bottleneck: a separate group reports a gold nanosheet sensor for hydrogen sulfide in exhaled breath, with small variability and high selectivity, and the ACS Nano paper cites a room-temperature sensor for ppb-level dimethyl sulfide based on UV-activated titanium dioxide nanoparticles.
The next step is the one the study points to: checking whether the gain seen on simulated samples holds in people with liver disease. Until that evaluation is done, the breath sensor remains a laboratory result.