Aube.Tuesday, 24 November 2026Support us

Aube.

News of progress
LabSingle source

Smart patch senses spinal clot pressure, releases drug

Languages for this article
Original · ENDEESFRITPT

Originally written in English. 6 languages available; yours is one click away.

Illustrative photo: Biomedical Engineering Laboratory
Illustrative photo: UC Davis College of Engineering · CC BY 2.0 · Wikimedia Commons

Blood that collects around the spinal cord after surgery can press on the nerves beside it. The result can be severe pain, muscle weakness or even paralysis. Early detection matters, yet following these clots over time is difficult, and conventional treatments may require additional surgery. A team led by professor Zong-Hong Lin at National Taiwan University has built a device that tries to address both problems at once.

The device is a biodegradable patch made of extremely thin fibers, composed of a biodegradable polymer and glycine, a naturally occurring amino acid. The fibers are piezoelectric, a property that lets them generate electrical signals when they are squeezed. That is what allows the patch to detect pressure changes without an external power source for sensing. In laboratory experiments, it produced electrical signals of approximately 8 volts under an applied pressure of 80 pascals.

The researchers also placed urokinase, a medication that helps dissolve blood clots, inside the fibers. When ultrasound is applied from outside the body, the fibers release the drug in a controlled manner. Under ultrasound, the patch released approximately six times more urokinase than when it was not stimulated. In laboratory blood clot experiments, the system achieved approximately 70% clot degradation. The team presents this as a way to deliver treatment when it is needed, rather than releasing drug continuously.

The work is not yet at the stage of patients. The authors state that further animal studies and clinical evaluations are necessary, and no timeline for them is given. If those steps succeed, patients recovering from spinal surgery could in principle be monitored and treated with the same device, with less need for further invasive procedures, as Lin hopes. For now, the gain belongs to the research: a single biodegradable material that senses and treats in the same place, demonstrated on the bench.

approximately 70%Clot degradation in laboratory blood clot experiments

Sources — read the originals(Paris time)

0000

Read next

Comments

Loading the thread…

Sign in to leave a comment. Sign in