Wavy copper tubes lift a prototype solar panel past 37% total yield

In May 2025, in Kermanshah in western Iran, a 180 W solar panel sat in the sun under 1,038 W/m2 of irradiance, at an average ambient temperature of 27°C. Water flowed through copper tubes fixed to its back, and the tubes were not straight: the team at Razi University had bent them into waves. The panel was doing two jobs at once. It made electricity, and the water carried away part of the heat it absorbed.
The question was whether the wave shape beat the conventional straight tubes. The researchers built three cooling assemblies, one with straight tubes and two with wavy tubes spaced 200 mm and 300 mm apart, each with a 50 mm wave height. Each one was tested at water flow rates from 200 to 800 mL/min, with inlet water held at 20°C. A test ran about 30 minutes, until conditions stabilised, and an uncooled module served as the reference. The team stresses that the module is commercially representative, unlike many small-scale studies.
The best combination, the wavy tube with a 200 mm spacing at 800 mL/min, cut the absorber plate temperature to about 49°C, against 64°C on the uncooled module, a drop of about 15°C. Electrical efficiency rose to 13.65%, from 12.63%, a gain of 1.02 percentage points. Thermal efficiency reached about 24%, against 18% for straight tubes, and total efficiency exceeded 37%, against about 31%. Most of the improvement therefore sits in the heat captured, not in the electricity.
The gain has a cost in hydraulic resistance. At 400 mL/min, the wavy tube with 200 mm spacing recorded about 1,200 Pa of pressure drop, against around 750 Pa for straight tubes at the same flow rate, so the water circuit has more resistance to overcome.
For a building that already has a PV panel and wants hot water, the message is that the same surface can deliver more total energy, with a bent copper circuit in place of a straight one. The results come from one prototype, tested over runs of about 30 minutes in one place. What changes today is a measured answer to a design question: bent tubes pull more heat out of a panel than straight ones, at the price of more pressure in the water loop.