Just under half of all MRI scans rely on a gadolinium-based contrast agent, and the metal does its work inside the body before leaving it. Gadolinium is held in a so-called chelate, a molecular cage, and it interacts with water in tissue to make some areas look brighter on the scanner. After the scan, the agent is excreted in urine and ends up in wastewater, where the metal stays locked in its cage in the long term. A team at the German Cancer Research Center (DKFZ), led by Leif Schröder, has now found a way to detect that metal in solution down to the micromolar range.
Pouco menos de metade de todas as ressonâncias magnéticas recorre a um agente de contraste à base de gadolínio, e o metal faz o seu trabalho dentro do corpo antes de ser eliminado. O gadolínio fica retido num chamado quelato, uma gaiola molecular, e interage com a água dos tecidos para tornar algumas zonas mais brilhantes no ecrã do aparelho. Após o exame, o agente é eliminado na urina e acaba nas águas residuais, onde o metal permanece preso na sua gaiola a longo prazo. Uma equipa do Centro Alemão de Investigação do Cancro (DKFZ), liderada por Leif Schröder, encontrou agora uma forma de detetar esse metal em solução até à gama micromolar.
The method combines two effects. The researchers use hyperpolarized xenon, a noble gas magnetized so that it produces a strong MRI signal. Xenon sits in a separate cage molecule, cryptophane-A, and produces two distinct signals: one for xenon bound in the cage, one for xenon floating free in the solution. When gadolinium is added, it displaces the xenon from the cage, so the bound signal shrinks and eventually disappears. “From the reduction in the xenon signal, we were able to determine the concentration of gadolinium outside the cage,” says Hannah Gerbeth, the study's lead author.
O método combina dois efeitos. Os investigadores usam xénon hiperpolarizado, um gás nobre magnetizado de forma a produzir um sinal forte de ressonância magnética. O xénon fica alojado numa molécula-gaiola separada, a criptofano-A, e produz dois sinais distintos: um para o xénon ligado à gaiola, outro para o xénon que flutua livremente na solução. Quando se adiciona gadolínio, este desloca o xénon da gaiola, pelo que o sinal ligado diminui e acaba por desaparecer. «A partir da redução do sinal do xénon, conseguimos determinar a concentração de gadolínio fora da gaiola», afirma Hannah Gerbeth, primeira autora do estudo.
The DKFZ team found that concentrations in the micromolar range can be measured under the conditions of the experiment, which makes the cage molecule a highly sensitive sensor. “This discovery shows that the unique properties of the interaction between gadolinium, xenon and the cage enable more sensitive detection than was possible in previous research using MRI,” Schröder says. The method also separates free gadolinium from the chelated form, which matters for both clinical use and monitoring of gadolinium-containing substances in the environment. Schröder stresses the need for such tools, not only for contrast agents but also for industrial processes. The results so far come from laboratory solutions.
A equipa do DKFZ concluiu que é possível medir concentrações na gama micromolar nas condições da experiência, o que faz da molécula-gaiola um sensor altamente sensível. «Esta descoberta mostra que as propriedades únicas da interação entre gadolínio, xénon e a gaiola permitem uma deteção mais sensível do que era possível em investigações anteriores com ressonância magnética», afirma Schröder. O método também separa o gadolínio livre da forma quelatada, o que é importante tanto para a utilização clínica como para a monitorização de substâncias que contêm gadolínio no ambiente. Schröder sublinha a necessidade de ferramentas deste tipo, não só para agentes de contraste, mas também para processos industriais. Os resultados até agora provêm de soluções de laboratório.
For clinicians and environmental monitoring teams, the gain is a more sensitive way to tell free gadolinium from the bound form that is currently excreted. The study does not say when such a tool could reach hospitals or water-treatment sites.
Para clínicos e equipas de monitorização ambiental, o ganho está numa forma mais sensível de distinguir o gadolínio livre da forma ligada, que atualmente é eliminada. O estudo não indica quando é que uma ferramenta deste tipo poderá chegar aos hospitais ou às estações de tratamento de água.
The next steps are already set. The scientists plan to test the sensor across other concentration ranges. They also want to find out whether other ions are bound by the cage, since such ions could interfere with the gadolinium measurement.
Os próximos passos já estão definidos. Os cientistas planeiam testar o sensor noutras gamas de concentração. Querem também descobrir se a gaiola se liga a outros iões, uma vez que esses iões poderiam interferir na medição do gadolínio.